There is more in this then just the convenience of access to the data from anywhere. For starters, there is no software to install as the monitoring application runs directly in a standard web browser. There is no system maintenance for the plant operators as they only have to install the sensors and wireless data acquisition modules. And the most important aspect of all is that this system reduces costs because the users do not have to own and operate the server's complex software and hardware. Instead, they get it all as a service.
Showing posts with label Condition monitoring. Show all posts
Showing posts with label Condition monitoring. Show all posts
Monday, August 2, 2010
Cloud Computing in Action
If you make the technology right, people will pick it up and embrace it sooner than you can imagine. In his video tutorial Tom Hoenig of GTI uses the InSite system to demonstrate remote condition monitoring at a plant in Rochester, NY area. What Tom does not mention is that he is monitoring that machine from his office in Manchester, NH and the application server that stores the data, does all the calculations, and delivers the user interface to his browser is running in a data center in Chicago and is maintained by InCheck. And yet, the application feels seamless as if everything is running on Tom's iBook.
Tuesday, February 16, 2010
Instrumentation - Dynamic Resoluiton
When sensor signals are being converted to data the capabilities of ADC (analog to digital converter) should be considered. The dynamic resolution of an ADC is related to a number of steps the original signal is approximated with. If the ADC has 10 bit resolution, that means that the full input range will be digitized using 2^10 (two to the power of ten) or 1024 steps. For many applications it is too crude, especially if the signal is not amplified. Typically, for vibration measurements ADCs with 16 or even 24 bits of resolution are used. For industrial vibration monitoring a 16 bit ADC is quite enough. A sensor with the sensitivity of 100 mV/g and the signal range of -10/+10V will have the smallest step of 3mg at 16 bit ADC. Dynamic resolution is sometimes listed in dB in device specifications.
If more dynamic resolution is needed, the signal can be amplified, or an ADC with higher resolution can be used. There are trade-offs with either method. An analog amplifier can introduce noise while a higher resolution ADC results in a more expensive device. There is a signal processing technique that can boost dynamic resolution through oversampling.
Wednesday, January 27, 2010
Instrumentation - Data Acquisition
Sensor signals have to be converted to data (digitized) before they can be processed and stored. This process is called data acquisition. For vibration data the best solution is to acquire a dynamic signal, the function of acceleration over time. This function can later be processed with several algorithms to yield valuable machine condition and diagnostic data. The data acquisition process assigns a number to every level of acceleration at equal time intervals. It takes place in a data acquisition device that contains a micro processor, an ADC (analog to digital converter), necessary filters, and other components. In addition, the data acquisition device has to have means for sending the data out for further processing and storage.
There are many decisions that have to be made about the data acquisition. Here are some of the questions that are typically asked about data acquisition:
How much data has to be collected?
What is the required sampling rate?
What is the proper ADC resolution?
How the signal has to be filtered?
From the practical standpoint these selections must be made behind the scene in software and not by the user. However, many data acquisition systems assume technically savvy users who know how to use these parameters. A more user friendly system should ask a different set of questions:
What is required frequency resolution?
What is required analysis bandwidth?
What is required dynamic resolution?
Answers to these questions help set up proper data acquisition parameters and they borderline with our next topic - Data Processing and Storage.
Saturday, January 16, 2010
Instrumentation -- Sensors
Since we are talking specifically about machine condition monitoring, our primary interest will be in vibration sensors. Over many years the standard vibration sensor has been an accelerometer. The sensing technology in a standard accelerometer is pretty much the same today as it was thirty years ago.
In spite of its wide use the standard accelerometer is not an ideal vibration sensor. It requires a charge amplifier that is usually built into the sensor body and an analog signal conditioner, which adds to the cost. Low frequency applications are challenging because the sensor is not sensitive to static acceleration while the dynamic acceleration is very low at low frequencies. These sensors require regular recalibration in condition monitoring applications. However the main issue with traditional accelerometers is cost. An accurate, temperature stable accelerometer with a wide frequency range can cost a few hundred dollars.
The good news is that soon this is going to change. New technology is already here and is waiting to be widely adopted. I am talking about MEMS accelerometers. The MEMS technology has been widely used for sensors and MEMS accelerometers are commonly used in electronic devices as motion sensors. Industrial applications could not benefit from the MEMS technology until last year when Analog Devices has released the ADXL001 accelerometer. Designed specifically for industrial applications, this accelerometer features a wide frequency range, high temperature stability, excellent low frequency characteristics, and does not need recalibration.
Sounds like a perfect vibration sensor? Well, not so fast. There is a gap between the sensor's microchip form factor and the industry's requirement for robustness. This sensor needs an appropriate packaging, in which the sensor will be sealed from the environment and have means to be mounted to a machine. InCheck Technologies is working on a version that a user will be able to permanently mount into a small hole in a bearing housing. The package will also include a temperature sensor microchip, forming a dual sensor.
Speaking about temperature sensors, MEMS sensors can compete with traditional thermocouples and RTD's in the -40°C to +125°C temperature range. Unlike RTD's MEMS temperature sensors produce linear output and unlike thermocouples they do not require external electronics.
Did I mention the main advantage of the MEMS sensors? Yes, they are pretty inexpensive. The ADXL001 is still a little pricey, but it already beats the traditional technology hands down. And since the MEMS output is compatible with standard ADC input, no addition analog electronic components are necessary. With machine monitoring applications the low cost will be the key to wide adoption. The future apparently is with the MEMS technology.
Thursday, January 14, 2010
Machine Health Monitoring
Assuming now that we are all on board for predictive maintenance, what do we do next? Our goal is to prevent failures, so, obviously, we need to monitor our machines. This could be done just by inspection (listening to noise, touch for temperature and vibration, visual inspection) or by collecting data. Since the inspection by perception is biased and hard to document, I personally prefer data. Specifically, if we are talking about rotating machines, we need vibration data. With proper processing the vibration data can help diagnose almost any mechanical problem, especially when the data is tracked over time. Other parameters can be monitored as necessary. Temperature, pressure, electrical parameters, etc. - all can yield valuable machine health data.
We will talk about manual "walk around" data collection on a separate occasion. For now we assume a permanent installation. Whether we collect data manually or install permanent sensors, the monitoring system has to have a few layers between Machines and Users that look like this:
Machines --> Instrumentation --> Communication --> Processing and Storage --> Presentation --> Users
Instrumentation layer consists of sensors and data acquisition hardware. To minimize cost of installation the data acquisition hardware should be installed close to the machines. Long sensor wires are not only expensive and hard to install, they sometimes cause deterioration of the analog signal and loss of accuracy. The instrumentation layer outputs data in digital format.
Communication layer transmits the data to a server where it is processed and stored. Today it would be a shame if we ignored standard network infrastructure that makes this transmission easy. Costs are drastically reduced by using standard off the shelf networking components. Standard Ethernet (wired or wireless) and the Internet are the best choice for the communication layer.
Processing and Storage layer is typically a dedicated server computer that runs a few key pieces of software - communication server, digital signal processor, and database. It also contains an alert generator that informs users if something goes wrong.
Presentation layer is a web portal where user can login to monitor the data and control the system. The presentation layer sends to user's browser a program that shows the data in graphic format, gives interactive access to stored data and to all machines regardless of their location. The web portal can be accessed from anywhere with a secure login.
Clearly, the above system architecture is somewhat simplified, but for the purposes of this discussion it is fine. The point we are trying to make here is that today's technology provides tools to make a very inexpensive system that can monitor machine health condition with high accuracy.
Next time we will talk about sensors.
Sunday, January 10, 2010
Welcome to InCheck Technologies blog!
Welcome!

In this blog we will be discussing various aspects of remote machine monitoring technology for predictive maintenance. This topic is very important in the industry. Remote monitoring helps machine users to organize machine maintenance in a proactive way, saving money in the process.
Anybody who uses industrial machines knows that they have to be maintained. What people sometimes don't realize is how much this maintenance costs over the life of a machine. So, let's take a look.
Each machine provides a specific service. When you are buying a pump, your goal is to obtain pumping service from it. The cost of pumping service however is not limited to the cost of the pump but has to include installation, energy cost, cost of maintenance, and, at the end of our pump's life, the cost of disposal. Surprisingly, the cost of maintenance is second only to energy costs and can be up to 35% of the total, leaving the initial cost (the cost of the pump and installation) behind at about 10 % of the total, see the diagram below.

Typical life cycle costs of an industrial pump (source: Hydraulic Institute)
Unfortunately, this is just the cost of regular maintenance activities. It does not include the cost of downtime or additional costs that are usually incurred if a machine fails suddenly. This is a real problem. Due to unexpected failures this cost can be dramatic. In many cases the service has to be restored as soon as possible, leaving little choice but paying extra for parts, labor, overtimes, and lost production capability. And we are not even talking about the cost of poor maintenance.
The answer to the challenge lies in a properly organized predictive maintenance program. The goal of such a program is to monitor health condition of each machine, track developing faults, and repair the machines before they fail. This is easier to say than to do. There are two parts in this endeavor - organizational and technological. We will be talking mostly of the technology part, occasionally touching on how to make it work from the organizational standpoint.